Design-Build for HVAC Repair, Golf Course at Cannon AFB, NM

Agency: DEPT OF DEFENSE
Level of Government: Federal
Category:
Opps ID: NBD00159525267771988
Posted Date: Jan 13, 2021
Due Date: Jan 21, 2021
Solicitation No: 1069920
Source: https://beta.sam.gov/opp/1a125...
Design-Build for HVAC Repair, Golf Course at Cannon AFB, NM
Active
Contract Opportunity
Notice ID
1069920
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
AFSOC
Office
FA4855 27 SOCONS LGC
General Information View Changes
  • Contract Opportunity Type: Sources Sought (Updated)
  • All Dates/Times are: (UTC-07:00) MOUNTAIN STANDARD TIME, DENVER, USA
  • Updated Published Date: Jan 13, 2021 01:01 pm MST
  • Original Published Date: Jan 12, 2021 02:57 pm MST
  • Updated Response Date: Jan 21, 2021 02:30 pm MST
  • Original Response Date: Jan 21, 2021 02:30 pm MST
  • Inactive Policy: 15 days after response date
  • Updated Inactive Date: Feb 05, 2021
  • Original Inactive Date: Feb 05, 2021
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: Z1AA - MAINTENANCE OF OFFICE BUILDINGS
  • NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors
  • Place of Performance:
    Cannon AFB , NM 88103
    USA
Description View Changes

Design-Build construction services to replace the current HVAC system for the Golf Course Clubhouse, Building 2206 located at Cannon AFB, NM. The current structure was constructed in 1994 and is approximately 7,000 square feet. The current system is a 25-ton single plenum system using 5 direct expansion split units with 5 evaporators. The project includes demolition of the HVAC system components; demolition and replacement of the surrounding block wall; resizing of equipment pad to accommodate new equipment. New air handling equipment shall use 4-pipe/two coil system with new air handler sized to the structure. Cooling to be an air-cooled Trane chiller; chiller/boiler to utilize water softening in the makeup. New system to utilize Allerton DDC and connected to the Cannon AFB EMCS. All work will be done according to the most up-to-date applicable Unified Facilities Criteria, Air Force Instructions, local, state and federal building codes.

1. The 27 Special Operations Contracting Squadron (27 SOCONS) is seeking information concerning the availability of capable contractors to provide non-personal services as follows:

2. Description of Services: Design-Build construction services to replace the current HVAC system for the Golf Course Clubhouse, Building 2206 located at Cannon AFB, NM. The current structure was constructed in 1994 and is approximately 7,000 square feet. The current system is a 25-ton single plenum system using 5 direct expansion split units with 5 evaporators. The project includes demolition of the HVAC system components; demolition and replacement of the surrounding block wall; resizing of equipment pad to accommodate new equipment. New air handling equipment shall use 4-pipe/two coil system with new air handler sized to the structure. Cooling to be an air-cooled Trane chiller; chiller/boiler to utilize water softening in the makeup. New system to utilize Allerton DDC and connected to the Cannon AFB EMCS. All work will be done according to the most up-to-date applicable Unified Facilities Criteria, Air Force Instructions, local, state and federal building codes.

a. NAICS: 238220 – Plumbing, heating, and Air Conditioning Contractors

b. S/B Size Standard: $16.5M

c. Estimated Magnitude of Construction: Between $500,000 and $1,000,000

2. This Request for Information (RFI) is issued for informational and planning purposes only. This is not a Request for Proposal (RFP). It is not to be construed as a commitment by the Government to issue a solicitation or ultimately award a contract. Responses will not be considered as proposals, nor will any award be made as a result of this RFI. The Air Force will NOT be responsible for any costs incurred by interested parties in responding to this RFI. Contact with Government personnel other than those specified in this RFI by potential offerors or their employees’ regarding this project is prohibited.

3. The Capability Statement should include general information, past performance and technical background describing your firm's experience in contracts requiring similar efforts to meet the program objectives. Interested parties shall not submit more than 10 single-sided, type-written pages using 12-point font or larger. Published literature may be any number of pages. At a minimum the following information is requested:

a. Company Cage Code, DUNS, name, address, point of contact, telephone number and e-mail address.

b. Bonding capability.

c. Any small business status (8(a), HUB Zone, veteran-owned, women-owned, etc).

d. Indicate your role as “Prime Contractor” and what functions for which you plan to self perform as a percentage of the total and those which you intend to use subcontractors.

e. If you indicated your roll will be a “Subcontractor” on Question 4, please indicate which functional areas you intend to cover.

f. Indicate if your company primarily does business in the government and/or commercial sector.

g. Indicate which NAICS code(s) your company usually performs under for government contracts.

4. For your business to be considered as a potential vendor for set aside purposes you must submit a Capabilities Statement as requested by this notice. Failure to do so may result in your business category not being considered as part of a decision by the government to set aside. The information requested by this RFI will be used within the Air Force to facilitate decision making and will not be disclosed outside the agency.

If your firm is capable of providing the requirements described above, please provide a Capability Statement to the contract administrator and contracting officer by the deadline indicated in this sources sought.

Attachments/Links
Contact Information
Contracting Office Address
  • CP 575 785 2321 110 E ALISON AVE BLDG 600
  • CANNON AFB , NM 88103-5321
  • USA
Primary Point of Contact
Secondary Point of Contact
History

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >